Elevated Serum Concentrations of Cobalt, Chromium, Nickel, and Manganese After Metal-On-Metal Alloarthroplasty of the Hip
A Prospective Randomized Study
Henrik Dahlstrand, MD, André Stark, MD, PhD, Lucas Anissian, MD, PhD, and Nils P. Hailer, MDz
The Journal of Arthroplasty Vol. 24 No. 6 2009
Abstract In this prospective randomized study, we investigate metal ion concentrations and clinical outcome 2 years after metal-on-metal (28 patients) or metal-on-polyethylene (26 patients) hip arthroplasty with 28-mm modular heads. Metal ion concentrations in patient serum were analyzed by high-resolution plasma mass spectrometry. The clinical outcome was almost identical in both groups with respect to the Harris hip score and the Medical Outcome Study Short Form–36; and on plain radiography, no signs of loosening occurred in any group. In the metal-on-metal group, concentrations of all investigated ions increased significantly when compared with preoperative values: cobalt, 15.3-fold (95%confidence interval [CI], 9.4-21.2); chromium, 5.2-fold (CI, 3.5-7.0); nickel, 2.1-fold (CI, 1.2-3.0); and manganese, 1.6-fold (CI, 1.3-2.0). In the metal-on-polyethylene group, a smaller but significant increase in the concentrations of cobalt and nickel occurred, whereas concentrations of the other ions did not change significantly.
- Results With the Cementless Spotorno Stem in Total Hip Arthroplasty
- Third-Generation Ceramic-on-Ceramic Bearing Surfaces in Revision Total Hip Arthroplasty
- Corrosion of a Hip Stem With a Modular Neck Taper Junction
- Elevated Serum Concentrations of Cobalt, Chromium, Nickel, and Manganese After Metal-On-Metal Alloarthroplasty of the Hip
- Long-term Results for the Uncemented Zweymuller/Alloclassic Hip Endoprosthesis
- In Vivo Wear Rate of the Birmingham Hip Resurfacing Arthroplasty
- The management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components
- Cementation of a Polyethylene Liner Into a Metal Acetabular Shell
- Blood metal ion concentrations after hip resurfacing arthroplasty
- Migration of the Trabecular Metal Monoblock Acetabular Cup System
- Risk factors for inflammatory pseudotumour formation following hip resurfacing
- Primary Total Hip Arthroplasty With Duraloc Cup in Patients Younger Than 50 Years
- Ten-year follow-up of the non-porous Allofit cementless acetabular component
- Ceramic-on-ceramic bearing surface and risk of revision due to dislocation after primary total hip replacement